Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.406
Filtrar
2.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
3.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479966

RESUMO

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , AVC Isquêmico , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , AVC Isquêmico/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
5.
Catheter Cardiovasc Interv ; 103(4): 511-522, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38415900

RESUMO

BACKGROUND: Double kissing (DK)-crush and T-stenting and small protrusion (TAP) techniques are gaining popularity, but the comparison for both techniques is still lacking. This study sought to retrospectively evaluate the long-term outcomes of DK-crush and TAP techniques in patients with complex bifurcation lesions. METHODS: A total of 255 (male: 205 [80.3%], mean age: 59.56 ± 10.13 years) patients who underwent coronary bifurcation intervention at a single-center between January 2014 and May 2021 were included. Angiographic features, procedure details, and in-hospital or long-term outcomes were assessed. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, target vessel myocardial infarction, or clinically driven-target lesion revascularization (TLR). The regression models were adjusted applying by the inverse probability weighted (IPW) approach to reduce treatment selection bias. RESULTS: The initial management strategy was DK-crush in 152 (59.6%) patients and TAP in 103 (40.4%) cases. The SYNTAX scores (24.58 ± 7.4 vs. 24.26 ± 6.39, p = 0.846) were similar in both groups. The number of balloon (6.32 ± 1.82 vs. 3.92 ± 1.19, p < 0.001) usage was significantly higher in the DK-crush group than in the TAP group. The rates of TLF (11.8 vs. 22.3%, p = 0.025) and clinically driven TLR (6.6 vs. 15.5%, p = 0.020) were significantly lower in the DK-crush group compared to the TAP group. The long-term TLF was significantly higher in the TAP group compared to the DK-crush group (unadjusted HR: 1.974, [95% CI: 1.044-3.732], p = 0.035 and adjusted HR [IPW]: 2.498 [95% CI: 1.232-5.061], p = 0.011). CONCLUSION: The present study showed that the DK-crush technique of bifurcation treatment was associated with lower long-term TLF and TLR rates compared to the TAP technique.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Sistema de Registros
6.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
8.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276659

RESUMO

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

9.
J Am Heart Assoc ; 13(2): e031111, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38214263

RESUMO

BACKGROUND: Despite the initial evidence supporting the utility of intravascular imaging to guide percutaneous coronary intervention (PCI), adoption remains low. Recent new trial data have become available. An updated study-level meta-analysis comparing intravascular imaging to angiography to guide PCI was performed. This study aimed to evaluate the clinical outcomes of intravascular imaging-guided PCI compared with angiography-guided PCI. METHODS AND RESULTS: A random-effects meta-analysis was performed on the basis of the intention-to-treat principle. The primary outcomes were major adverse cardiac events, cardiac death, and all-cause death. Mixed-effects meta-regression was performed to investigate the impact of complex PCI on the primary outcomes. A total of 16 trials with 7814 patients were included. The weighted mean follow-up duration was 28.8 months. Intravascular imaging led to a lower risk of major adverse cardiac events (relative risk [RR], 0.67 [95% CI, 0.55-0.82]; P<0.001), cardiac death (RR, 0.49 [95% CI, 0.34-0.71]; P<0.001), stent thrombosis (RR, 0.63 [95% CI, 0.40-0.99]; P=0.046), target-lesion revascularization (RR, 0.67 [95% CI, 0.49-0.91]; P=0.01), and target-vessel revascularization (RR, 0.60 [95% CI, 0.45-0.80]; P<0.001). In complex lesion subsets, the point estimate for imaging-guided PCI compared with angiography-guided PCI for all-cause death was a RR of 0.75 (95% CI, 0.55-1.02; P=0.07). CONCLUSIONS: In patients undergoing PCI, intravascular imaging is associated with reductions in major adverse cardiac events, cardiac death, stent thrombosis, target-lesion revascularization, and target-vessel revascularization. The magnitude of benefit is large and consistent across all included studies. There may also be benefits in all-cause death, particularly in complex lesion subsets. These results support the use of intravascular imaging as standard of care and updates of clinical guidelines.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Trombose , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Ultrassonografia de Intervenção/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Trombose/etiologia , Resultado do Tratamento , Morte
10.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
15.
Artigo em Inglês | MEDLINE | ID: mdl-37931791

RESUMO

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

16.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37933728

RESUMO

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Angiografia Coronária/métodos
17.
J Neurol Sci ; 454: 120848, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37939626

RESUMO

INTRODUCTION: COVID-19 pandemic had a great impact on outcome in SARS-CoV-2 positive patients with ischemic stroke during the first wave in Italy. Few data are available on outcome stratified by sex. METHODS: The Italian Society of Hospital Neuroscience conducted a multi-center, retrospective, observational study on neurological complications in COVID-19 patients with ischemic stroke. All the patients admitted from March 1st to April 30th, 2020 in 20 Neurology Units in Northern Italy were recruited. Demographical and clinical features, treatment and outcome data were compared focusing on sex differences. RESULTS: 812 patients with ischemic stroke were enrolled, of whom 129 with COVID-19; males were 53.8%. In-hospital mortality in COVID-19 patients was 35.3% in males and 27.9% in females while 8.5% in male and 5.8% in female patients without COVID-19. SARS-CoV-2 positive patients had a higher frequency of stroke of undetermined etiology, than negative ones (32.8% vs 22.5%; p = 0.02), especially in females compared to males (36.1% vs 27.9%), albeit without statistical significance. Male patients with SARS-CoV-2 were more likely to require cPAP (30.9% vs 14.8%; p = 0.03), endotracheal tube (14.9% vs 3.3%; p = 0.02) and reperfusion strategies (29.4% vs 11.5%; p = 0.01) than females, as well as to have a higher CRP and D-dimer. These elements together with older age, a total anterior circulation stroke and lymphopenia were predictors of a worse outcome. DISCUSSION: Our study detected some differences due to sex in ischemic stroke with and without COVID-19, supporting the possibility to perform sex analyses for SARS-CoV-2 positive patients for a better clinical management.


Assuntos
COVID-19 , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , COVID-19/epidemiologia , SARS-CoV-2 , AVC Isquêmico/epidemiologia , Estudos Retrospectivos , Pandemias , Caracteres Sexuais , Acidente Vascular Cerebral/terapia , Itália/epidemiologia
18.
Catheter Cardiovasc Interv ; 102(6): 1020-1033, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37855169

RESUMO

BACKGROUND: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. AIMS: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). METHODS: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9-12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. RESULTS: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3 , p = 0.40) at 9-12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). CONCLUSIONS: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.


Assuntos
Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Implantes Absorvíveis , Everolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Sirolimo/efeitos adversos , Tomografia de Coerência Óptica , Resultado do Tratamento
20.
JACC Cardiovasc Interv ; 16(23): 2884-2896, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37877914

RESUMO

BACKGROUND: There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD). OBJECTIVES: This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB. METHODS: This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain. RESULTS: Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (Pnoninferiority = 0.173), with an absolute difference of -0.23 mm (95% CI: -0.37 to -0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively. CONCLUSIONS: The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.


Assuntos
Angioplastia Coronária com Balão , Paclitaxel , Sirolimo , Doenças Vasculares , Humanos , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Paclitaxel/uso terapêutico , Bifenilos Policlorados , Estudos Prospectivos , Sirolimo/uso terapêutico , Resultado do Tratamento , Doenças Vasculares/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...